Description
The fiber optic drop cable patch cord has two connectors in each end of the cable to make connection; pigtail cable is one cable with a connector.
The connectors are with SC type, ceramic ferrule to be polished as APC . A SM convertion patch cord is with two different connector.
FTTH Optical fiber patch cord is made up by optical communication unit, strengthen pieces and the sheath composition, that is put the optical
communication unit in the middle, both sides parallel place two root non-metallic strengthen members or metal strengthening component
phosphate steel wire, finally squeeze the black or color sheath into cable.
The cable length(1m, 2m, 3m, 5m, 10m, 20m, 30m, 50m, 100, 200m,300, or more) can be customized.
Features
1.Cost effective solution for in house termination.
2.Low insertion loss and added loss.
3.Height of attenuation.
4.The material in the jumpel cable are all-weather and UV-resistant.
5.Mechanical performance: IEC 61754-4 standard.
6.RoHS and REACH materials compliant.
7.Cable diameter Range: 2.0*3.0mm, 2.0*5.0mm..
Application
FTTH network for indoor and outdoor
Local Area Network
Building Cabling Network
Interconnect between instruments, terminal box and communication
Dimensional Diagrams
1. SCAPC FTTH Flat Drop Patch Cord 2.0*3.0mm Cable
2. SCAPC FTTH Flat Drop Patch Cord 2.0*5.0mm Cable
Patch cord versions
Jumper tolerance requirement | |
Overall length (L) (M) |
length of tolerance(CM) |
0<L≤20 |
+10/-0 |
20<L≤40 |
+15/-0 |
L>40 |
+0.5%L/-0 |
Cable Structure
Cable Parameters
Cable Count |
Out sheath Diameter (MM) |
Weight (KG) |
Minimum allowable Tensile Strength (N) |
minimum allowable Crush Load (N/100mm) |
Minimum Bending Radius (MM) |
Storage temperature (℃) |
|||
short term |
long term |
short term |
long term |
short term |
long term |
||||
1 |
(2.0±0.1)×(3.0±0.2) |
8 | 100 | 50 | 50 | 100 | 20D |
10D |
-20 ~~ +60 |
Cable Count |
Out sheath Diameter (MM) |
Weight (KG) |
Minimum allowable Tensile Strength (N) |
minimum allowable Crush Load (N/100mm) |
Minimum Bending Radius (MM) |
Storage temperature (℃) |
|||
short term |
long term |
short term |
long term |
short term |
long term |
||||
1 |
(2.0±0.2)×(5.0±0.3) |
21.7 | 400 | 200 | 2200 | 1000 | 20D |
10D |
-20 ~~ +60 |
Optical Characteristics
Item |
Parameter |
Reference |
|||
Single mode |
Multimode |
||||
Standard |
Elite |
Standard |
Elite |
||
Insertion loss |
Typical≤0.30dB Max≤0.75dB |
Typical≤0.15dB Max≤0.35dB |
Typical≤0.50dB Max≤0.25dB |
Typical≤0.10dB Max≤0.35dB |
IEC 61300-3-34 |
Return loss |
≥ 50dB (PC) ≥ 60dB (APC) |
≥ 55dB (PC) ≥ 65dB (APC) |
≥30dB(PC) |
≥30dB(PC) |
IEC 61300-3-6 |
End-Face Geometry
Item |
UPC (Ref: IEC 61755-3-1) |
APC (Ref: IEC 61755-3-2) |
Radius of curvature (mm) |
10 to 25 |
5 to 12 |
Fiber height (nm) |
-100 to 100 |
-100 to 100 |
Apex offset (μm) |
0 to 50 |
0 to 50 |
APC angle (°) |
/ |
8° ±0.2° |
Key error (°) |
/ |
0.2° max |
End-Face Qualty (SM)
Zone |
Range (μm) |
Scratches |
Defects |
Reference |
A: Core |
0 to 25 |
None |
None |
IEC 61300-3-35:2015 |
B: Cladding |
25 to 115 |
None |
None |
|
C: Adhesive |
115 to 135 |
None |
None |
|
D: Contact |
135 to 250 |
None |
None |
|
E: Rest of ferrule |
None |
None |
End-Face Qualty (MM)
Zone |
Range (μm) |
Scratches |
Defects |
Reference |
A: Core |
0 to 65 |
None |
None |
IEC 61300-3-35:2015 |
B: Cladding |
65 to 115 |
None |
None |
|
C: Adhesive |
115 to 135 |
None |
None |
|
D: Contact |
135 to 250 |
None |
None |
|
E: Rest of ferrule |
None |
None |
Mechanical Characteristics
Test |
Conditions |
Reference |
Endurance |
500 matings |
IEC 61300-2-2 |
Vibration |
Frequency: 10 to 55Hz, Amplitude: 0.75mm |
IEC 61300-2-1 |
Cable retention |
100N (main cable); 50N (connector part) |
IEC 61300-2-4 |
Strength of coupling mechanism |
80N for 2 to 3mm cable |
IEC 61300-2-6 |
Cable torsion |
15N for 2 to 3mm cable |
IEC 61300-2-5 |
Fall |
10 drops, 1m drop height |
IEC 61300-2-12 |
Static lateral load |
1N for 1h (main cable); 0.2N for 5min (ranch part) |
IEC 61300-2-42 |
Cold |
-25°C, 96h duration |
IEC 61300-2-17 |
Dry heat |
+70°C, 96h duration |
IEC 61300-2-18 |
Change of temperature |
-25°C to +70°C, 12 cycles |
IEC 61300-2-22 |
Humidity |
+40°C at 93%, 96h duration |
IEC 61300-2-19 |